QSV Series
Ultrasonic Velocity Gauges
Fast, precise and versatile
The speed meters of the QSV Series are ideal for determining type (gray / nodular) and percentage of nodularity in foundries, as well as identifying different materials.
This procedure requires knowing the thickness of the piece, which can be entered into the equipment manually or by means of a gauge to speed up the measurement.
QSV
Outstanding features
Measuring range from
1 to 500mm
Velocity from 100 to 19999m/s
0.01mm resolution
Digital caliper compatible
Alarms
Alarms Minimum Value Hold
Memoria de 5000 datos
AUTO 1-step calibration
(no Cal Key)
USB for data transfer 1
Basic statistics in measurement
Velocity calculation and adjustment
5 year warranty on the electronic unit
1. Model with Datalogger. dmq DataCenter at no charge.
Transducers
We offer a wide variety of transducers that allow us to cover a measurement range from 0.8mm to 500mm in the most diverse attenuations, conditions and materials.
2MHz transducer
Ideal for measuring materials with attenuation and/or large thicknesses.
2MHz transducer Ø12mm. 90°
Range: 4 to 500mm | Temp. -10 to 40°C
5MHz transducers
General use transducers.
5MHz transducer Ø10mm. 90°
Range: 1 to 300mm | Temp. -10 to 40°C
5MHz transducer Ø10mm. Straight
Range: 1 to 300mm | Temp. -10 to 40°C
2MHz transducer Ø12mm. 90°
Ideal for measuring materials with attenuation and/or large thicknesses.
Range: 4 to 500mm | Temp. -10 to 40°C
5MHz transducer Ø10mm. 90°
General purpose angled transducer.
Range: 1 to 300mm | Temp. -10 to 40°C
5MHz transducer Ø10mm. Straight
General use straight transducer.
Range: 1 to 300mm | Temp. -10 to 40°C
DMQ interface to connect digital caliper
Streamline your measurements and ensure reliable values by connecting a caliper to your QSV incorporating the DMQ interface cable to enter the thickness of the piece to be measured, a necessary parameter for calculating the ultrasonic velocity.
We have DMQ connection interfaces for InSize and Mitutoyo digital calipers.
DMQ interface for InSize digital caliper.
Part Nº: QSC001
Length: 1 meter.
(eg: Caliper model 1108-150)
DMQ interface for Mitutoyo digital caliper.
Part Nº: QSC002
Length: 1 meter.
(eg: Caliper model 500-171-30B / 500-172-30B)
DMQ interface for InSize digital caliper.
Part Nº: QSC001
Length: 1 meter.
(eg: Caliper model 1108-150)
DMQ interface for Mitutoyo digital caliper.
Part Nº: QSC002
Length: 1 meter.
(eg: Caliper model 500-171-30B / 500-172-30B)
Applications
Ideal for measuring:
- Determine cast iron types.
- Calculate percentage of nodularity 2
- Catalog materials by their speed of propagation
2. The electronic unit does NOT perform the nodularity calculation.
Modelos
Swipe the table horizontally to fully display its content.
Models |
data output |
DMQ interface output for caliper |
---|---|---|
QSV B | ||
QSV DL |
Compatible with DataCenter
In our QSV DL model with a Datalogger, you can connect to a PC to manage data using dmq DataCenter software available at no charge.
See DataCenterModel upgrades
Have your needs changed after your original purchase?
With model upgrade licenses you can change your existing model to one that meets your new application and or features needs without having to purchase a whole new instrument.
ContactQSV General Specifications
Dimensions
79 x 117 x 32mm
(3.11 x 4.6 x 1.26in)
Weight
182g
(0.40lbs)
Range 3
Pulse-Echo:
0.6 to 500mm
(0.023 to 19.7in)
Resolution
0.01mm
(0.001in)
Velocity
100 to 19999m/s: 1m/s
(3.94 to 787.36in/ms: 0.04in/ms)
Power
AA x2
Battery life
60 hours 4
Certificates
Certificate of Conformity
3. Depending on the transducer and the material.
4. Display light off.
Ready to use
Delivered in a high impact carrying case, inside you will find:
- QSV electronic unit
- Coupling gel
- 2MHz Transducer
- USB cable 5
- User manual
- Pendrive with dmq DataCenter 5
- Certificate of conformity
5. QSV DL model
Measurement - QSV
What's inside the QSV B
What's inside the QSV DL
QSV electronic unit - Front and Back
QSV electronic unit - Power supply: AA x2
QSV electronic unit - Connectors + USB data output + DMQ interface output for caliper
QSV electronic unit - Tilt Feet
You can find more videos in our YouTube channel.
Go YoutubeAccessories and Consumables
QSS201
2MHz transducer Ø12mm. 90°
Ideal for measuring materials with attenuation and/or large thicknesses.
Range: 4mm to 500mm | Temp. -10 to 40°C
QSS501
5MHz transducer Ø10mm. 90°
General purpose angled transducer.
Range: 1mm to 300mm | Temp. -10 to 40°C
QSS511
5MHz transducer Ø10mm. Straight
General use straight transducer.
Range: 1mm to 300mm | Temp. -10 to 40°C
QSC001
Interface cable for InSize digital caliper.
Length: 1m
QSC002
Interface cable for Mitutoyo digital caliper.
Length: 1m
Coupling gel
Plastic bottle with pouring spout.
working temperature -10 to 40°C
- QSG005: Coupling gel in plastic bottle with pouring spout of 50cc (1.76oz)
- QSG010: Coupling gel in plastic bottle with pouring spout of 100cc (3.52oz)
- QSG100: Coupling gel in plastic container of 1kg (2.2lbs)
- QSG500: Coupling gel in plastic container of 5kg (11lbs)
QAI001
Thermal printer for dmq instruments 6
Speed: 90mm/s
Resolution: 203dpi
Weight: 134g
Dimensions: 105 x 75 x 45mm
6. Does not include connecting cable
QAC001
Cable to connect a thermal printer to dmq instruments
Adapting cable with mini USB to mini USB connectors.
QSP001
Silicone protective cover
Color: Yellow
Certificates and International Standards
Included certificate
Certificate of Conformity
This certificate accompanies all DMQ equipment, they are made based on secondary calibration blocks, procedures and internal DMQ standards.
- QSF310: Certificate of Conformity for Electronic Unit in E1 mode.7
- QSF313: Additional Certificate of Conformity per Transducer.
7. For QSV models with their main transducer.
Optional certificates
Optionally, we offer Certificates with traceability for electronic unit:
Certificate with ILAC/OAA traceability
Certificate that is made based on calibration blocks or instruments certified by the ILAC/OAA laboratory. A copy of the traceable certificates is attached to the Certificate with Traceability.
Check validity of the certifying organization in your region.
- QSF210: Certificate with ILAC/OA traceability for QS electronic unit in E1 mode8
- QSF213: Certificate with ILAC/OA traceability per additional transducer.
8. For QSV models with their main transducer.
I am Quokke, the mascot.
Choose us and be as happy as I am!
See products
ALL RIGHTS RESERVED.